Fracture Strength of Aged Monolithic and Bilayer Zirconia-Based Crowns

Abstract

The purpose of this study was to evaluate the effect of design and surface finishing on fracture strength of yttria-tetragonal zirconia polycrystal (Y-TZP) crowns in monolithic (1.5 mm thickness) and bilayer (0.8 mm zirconia coping and 0.7 mm porcelain veneer) configuration after artificial aging. Bovine incisors received crown preparation and Y-TZP crowns were manufactured using CAD/CAM technique, according to the following groups (n = 10): Polished monolithic zirconia crowns (PM); Glazed monolithic zirconia crowns (GM); Bi-layer crowns (BL). Crowns were cemented with resin cement, submitted to artificial aging in a chewing simulator (2.5 million cycles/80 N/artificial saliva/37 °C), and tested for fracture strength. Two remaining crowns referring to PM and GM groups were submitted to a chemical composition analysis to measure the level of yttrium after aging. One-way ANOVA and Tukey's test (P = .05) indicated that monolithic zirconia crowns presented similar fracture strength (PM = 3476.2 N ± 791.7; GM = 3561.5 N ± 991.6), which was higher than bilayer crowns (2060.4 N ± 810.6). There was no difference in the yttrium content among the three surfaces evaluated in the monolithic crowns. Thus, monolithic zirconia crowns present higher fracture strength than bilayer veneered zirconia after artificial aging and surface finishing does not affect their fracture strength.

Description

Keywords

Y-TZP, Fracture resistance

Citation

DOI

10.1155/2015/418641

ISSN

2314-6133

Creative Commons

Creative Commons URI

Items in TSpace are protected by copyright, with all rights reserved, unless otherwise indicated.